Waferpedia

Comparison ledger

34465 Aversus-Mist 850 Electronic Air Filter

Keysight 34465 A, Tri -Mist 850 Electronic Air Filter, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
34465 AKeysight
OEMKeysightTri
CategoryLab & Support EquipmentLab & Support Equipment
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyKeysight 34465 ATri -Mist 850 Electronic Air Filter
Cited variants
  • 34460ATruevolt Series[1]
  • 34461ATruevolt Series[1]
  • 34470ATruevolt Series[1]
—
Specifications
Digits of resolution6½[1]—
Basic DC voltage accuracy (1 year, TCAL ±5°C)0.0030% of reading + 0.0004% of range (10 V range)[1]—
Max reading rate (standard digitizing)5,000 readings/s[1]—
Max reading rate (optional digitizing)50,000 readings/s[1]—
Memory (standard)50,000 readings[1]—
Memory (optional)2 million readings[1]—
DC voltage ranges100 mV to 1000 V[1]—
AC voltage ranges (RMS)100 mV to 750 V[1]—
DC current ranges1 μA to 10 A[1]—
AC current ranges (RMS)100 μA to 10 A[1]—
2- and 4-wire resistance ranges100 Ω to 1000 MΩ[1]—
Capacitance ranges1.0 nF to 100.0 μF[1]—
Frequency range3 Hz to 300 kHz[1]—
Temperature measurementRTD/PT100, thermistor, thermocouples (K,J,T,E,N,R)[1]—
DisplayColor graphical, 4.3-inch, dual line display[1]—
Interface - USBYes[1]—
Interface - LAN/LXI CoreOptional[1]—
Interface - GPIBOptional[1]—
Basic DCV accuracy30 ppm[1]—
Max reading rate (standard)5,000 rdgs/s[1]—
Max reading rate (with DIG option)50,000 rdgs/s[1]—
Volatile reading memory (standard)50,000 rdgs[1]—
Volatile reading memory (with MEM option)2,000,000 rdgs[1]—
AC voltage ranges100 mV to 750 V[1]—
AC current ranges100 μA to 10 A[1]—
Resistance ranges100 Ω to 1,000 MΩ[1]—
Temperature measurement typesRTD/PT100, thermistor, thermocouples[1]—
Weight (34461/65/70A)3.76 kg (8.3 lb)[1]—
Bench dimensions (W x H x D)261.2 mm x 103.8 mm x 303.2 mm[1]—
Standard interfacesUSB, LAN/LXI core, optional GPIB[1]—
SeriesTruevolt[2]—
DC Voltage Accuracy (1 year, 10 V range)0.0030% of reading + 0.0004% of range[1]—
Maximum Reading Rate (DC, standard)5,000 readings/s[1]—
Maximum Reading Rate (DC, with option)50,000 readings/s[1]—
Memory (with option)2 million readings[1]—
Measurement FunctionsDCV, ACV, DCI, ACI, 2-wire/4-wire resistance, capacitance, frequency, period, temperature (RTD, thermistor, thermocouple), diode, continuity[1]—
Basic DCV Accuracy (1 year, 10 V range)30 ppm[1]—
Rear Panel I/O Interfaces (standard)LAN/LXI, USB, external trigger[1]—
Max reading rate5,000 rdgs/s (standard), 50,000 rdgs/s optional[1]—
Memory50,000 readings standard, 2 million optional[1]—
Weight3.76 kg (8.3 lb)[1]—
InterfacesLAN/LXI, USB, optional GPIB[1]—
AutocalibrationACAL capable[1]—

Plan your fab

Building a Lab & Support Equipment process? Get a complete equipment list.

Open the fab equipment planner →
Sources (2)Every fact above is drawn from these public sources
  1. [1]cdn1.npcdn.netcdn1.npcdn.net
  2. [2]manualslib.commanualslib.com