KLA .498 PSL Wafer, Nikon Eclipse LV 100 ND, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
OEMKLANikon
CategoryMetrology & InspectionMetrology & Inspection
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones—2026 End of life
Control system——
Generation——
FamilyKLA .498 PSL WaferNikon Eclipse LV 100 ND
Cited variants—
  • ECLIPSE LV100ND POL/DS[1]
Specifications
ConfigurationNIST Traceable[2]—
NIST traceabilityYes[2]—
Manufacturer—Nikon[3]
Model—Eclipse LV 100 ND[3]
Optical system—CFI60 infinity[4]
Illumination—New illuminator brighter than 100 W; 12 V-50 W halogen lamp; built-in 12 V-50 W DC transformer; precentered lamphouse with rear mirror; fly-eye lens built-in; ND8 and NCB11 filters detachable[4]
Focusing—Coaxial coarse/fine focus knob; focus stroke 30 mm; coarse 14 mm per rotation; fine 0.1 mm per rotation; minimum reading in 1 μm increments[4]
Eyepiece—10x; F.O.V. 22; CM type with crosshair and micrometer scale; eyepiece graticule for asbestos[4]
Tube—P-TT3 trinocular tube for polarizing microscopy; with protrusions for eyepiece rotation prevention[4]
Polarizing intermediate tube—Analyzer detachable; orthoscopic and conoscopic observations switchable; plate/compensator slot; focusing and centering Bertrand lens[4]
Analyzer—360° rotary dial; minimum reading angle 0.1°[4]
Nosepiece—Reversed centering quintuple nosepiece, detachable, with DIN compensator slot[4]
Stage—High-precision circular graduated stage; rotatable 360° horizontally; fixed position available; graduated in 1° increments with 0.1° readings; 45° click stops; attachable mechanical stage with vernier 0.1 mm[4]
Condenser—LV-CUD Universal Condenser Dry (NA 0.9); D-C PH1, D-C PH2 and LV-C 2-4x Lens required; P Swing-out Condenser option[4]
Polarizer—C-SP simple polarizer; one-touch swing-out type[4]
Objectives—Polarizing: CFI Achromat P 4X, P 10X, LWD P 20X, P 40X, P 100X; Oil Dispersion: CFI Achromat R-DS 10X, CFI Plan Achromat C-DS 10X, CFI Plan Fluor R-DS 40X[4]
Compensators—P-CL 1/4 λ & tint plate, quartz-wedge compensator or Sénarmont compensator can be inserted into the polarizing intermediate tube slot[4]
Measuring filter—IF546/12 retardation filter (ø45 mm)[4]
Power consumption—1.2 A/75 W[4]
Magnification capability for dispersion staining—Up to 400x[1]
Maximum sample size—150 x 150 mm[5]
Weight—Approximately 9.6 kg[5]
OEM—Nikon[3]
Application/magnification note—Accessories enable dispersion staining observation at up to 400x magnification[1]

Plan your fab

Building a Metrology & Inspection process? Get a complete equipment list.

Open the fab equipment planner →
Sources (5)Every fact above is drawn from these public sources
  1. [1]microscope.healthcare.nikon.commicroscope.healthcare.nikon.com
  2. [2]inventory listing
  3. [3]Equipment inventory listing
  4. [4]microscope.healthcare.nikon.commicroscope.healthcare.nikon.com
  5. [5]exceltechnologies.comexceltechnologies.com