Agilent 6890 Gas Chromatography, Agilent 6890 GC, Agilent 6890 GC-MS, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
6890 GCAgilent
6890 GC-MSAgilent
OEMAgilentAgilentAgilent
CategoryThermal / Diffusion—Precision Optics
Wafer size———
Process node———
Introduced———
Production run———
Lifecycle———
Lifecycle milestones—2015 OEM support ended—
Control system———
Generation———
FamilyAgilent 6890Agilent 6890Agilent 6890
Cited variants——
Specifications
ConfigurationIncludes:[2]With[4]With 5973 MSD[8]
InjectorSplit-splitless (standard), others available[2]——
Oven temperatureAmbient +4 - 450 'C[2]——
Oven ramps / plateaus6-7[2]——
Carrier gasesHelium, hydrogen, nitrogen, argon[2]——
Electronic pnuematic controlAuto pressure regulation for split/splitless, septum purge[2]——
Carrier gas control modesConstant pressure and flow modes; pressure and flow programmable[2]——
Pressure range0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected[2]——
Retention-time lockingRTL ready[2]——
Flow controlCompatible with optional microfluidics controller[2]——
MakeAgilent[2]——
Model6890[2]6890 GC[4]—
Electronic pneumatic controlAuto pressure regulation for split/splitless, septum purge[2]Controls all gas pressures and flows[5]—
Mainframes6890A, 6890A Plus, and 6890N[1]——
Communication6890A uses HPIB (GPIB); 6890A Plus uses HPIB and can be upgraded to LAN; 6890N comes standard with LAN[1]——
EPC architecture13-channel digital EPC[3]——
Pressure accuracy±0.01 psi[3]——
Temperature stability±0.01 °C[3]——
Oven range–60 to 450 °C[3]4 to 450°C[5]—
Oven ramp rateUp to 120 °C/min[3]——
Data acquisition rateUp to 100 Hz[3]——
Retention time lockingEnabled for cross-instrument method transfer[3]——
InjectorsSplit-splitless (standard), others available[2]——
Detector optionsFID, uECD, TCD, PID, FPD, NPD, PDD, MSD, Triple Quadrupole TQ Mass Spec[1]——
Injection portsSplit/Splitless Inlet, Cool On-Column Inlet, Purged Packed Inlet, PTV Inlet, Volatiles Interface[1]——
OriginUSA[3]——
Operational age5–7 years[3]——
Warranty6 months[3]——
Regulatory complianceDesigned for GLP/GMP environments with audit-trail-capable data handling[3]——
Software platformOpenLAB CDS ChemStation (legacy-compatible)[3]——
EPC control13-channel digital electronic pressure control (EPC), pressure accuracy ±0.01 psi[3]——
Temperature programOven ramp rate up to 120 C/min, temperature stability ±0.01 C[3]——
Retention Time Locking (RTL)Enabled for cross-instrument method transfer[3]——
Manufacturer—Agilent[4]—
Equipment type—Gas Chromatography[4]—
Inlet type—Split/Splitless inlet[5]—
Inlet count—Up to two inlets[5]—
Detector count—Up to three detectors[5]—
Oven programming—20 ramps, 21 plateaus[5]—
Fast ramp rate—To 75°C/min on a 120 V oven[5]—
EPC resolution—0.001 psi, 0.05 mL/min[5]—
Communications—HPIB communications[5]—
Included detector—Flame Ionization Detector (FID)[5]—
Included detector configuration—Dual FID[6]—
Included components—HP 5973 MSD, Agilent 7683 Injector, Agilent 7683 Autosampler[4]—
Training material—Agilent 6890 GC and ChemStation Operation[7]—

Plan your fab

Building a Thermal / Diffusion process? Get a complete equipment list.

Open the fab equipment planner →
Sources (8)Every fact above is drawn from these public sources
  1. [1]aimanalytical.comaimanalytical.com
  2. [2]inventory listing
  3. [3]instrumenthive.cominstrumenthive.com
  4. [4]inventory listing
  5. [5]gentechscientific.comgentechscientific.com
  6. [6]gentechscientific.comgentechscientific.com
  7. [7]community.agilent.comcommunity.agilent.com
  8. [8]inventory listing