Attribute
AST-1100Despatch
OEMDespatchYES
CategoryThermal / DiffusionThermal / Diffusion
Wafer size300mm300mm
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyDespatch AST-1100YES 450
Specifications
Wafer sizeDesigned for 300 mm silicon wafers; also suitable for 200 mm wafers[1]Capacity is two 25 wafer cassettes in a batch process (50 wafers at a time) - 300mm FOUP[2]
Tool typeAutomated photowhite bake tool[1]—
Tool capacity50 wafers with standard two-chamber configuration[1]—
Temperature uniformity+/-1.0 °C between wafers and across all 25 wafers in the chamber at dunk temperature[1]—
Maximum temperature175 °C[1]—
AtmosphereInert atmosphere[1]—
CoolingActive cooling for rapid cool down[1]—
FiltrationHEPA filter[1]—
DimensionsApproximately 262 cm wide and 224 cm long[1]—
Automation featuresSupports two front-opening unified pod (FOUP) load stations, a class 1 cleanroom-compatible robot, and an optically based class 1 laser cassette imaging sensor[1]—
ComplianceMeets SEMI S2/S8 and SEMATECH appendices A, B, and C[1]—
Communication standardsMeets 300 mm SEMI communications standards[1]—
OptionsFOUP ID reader, 2-level monitoring, wafer ID reader, uninterruptible power supply (UPS)[1]—
Chamber Material—316L Stainless Steel[2]
Operation Temperature—ambient to 450°C (option high temp version: Ambient to 550°()[2]
Process Gas Inputs—1 standard up to 3 optional[2]
Configuration—Preheated N, (Process Gas)[2]
Mass Flow Controllers—optional, up to 3[2]
Laminar Flow Filter—100 micron Mott'" plate filter[2]
Cleanliness—particle reduction in most applications[2]
OEM—YES[2]
Model—450 PB 12[2]
Category—Thermal / Diffusion[3]
Capacity—Two 25-wafer cassettes in a batch process (50 wafers at a time)[2]
FOUP compatibility—300mm FOUP[2]
Wafer handling—Uses wafer cassette; wafers are manually brought to the machine and loaded inside[2]
Operation temperature—Ambient to 450°C[2]
Gas delivery—1 standard up to 3 optional[3]
Process gas—Preheated N2[2]
Vacuum—Alternate vacuum valve for process vacuum[3]
Vacuum plumbing—VCR[3]
Number of Recipes—8 temperature profiles (up to 200 with YES - DAQ-LR option)[2]
Temperature—Ambient to 450°C with LED temperature and set point displays[2]
Voltage—208V, 3 Phase 50/60 Hz, 40 amps[2]
Oxygen Concentration—10 ppm over background[2]