The Agilent N 9020 A Signal Analyzer is an MXA X-Series signal analyzer. The Agilent N 9020 A Signal Analyzer has frequency coverage of 10 Hz to 3.6 GHz, 8.4 GHz, 13.6 GHz, or 26.5 GHz depending on option. The Agilent N 9020 A Signal Analyzer has a standard analysis bandwidth of 10 MHz.[1][2]
The N9020A is part of the MXA X-Series of signal analyzers. The instrument is available with several frequency range options: Option 503 covers 20 Hz to 3.6 GHz, Option 508 covers 20 Hz to 8.4 GHz, Option 513 covers 20 Hz to 13.6 GHz, and Option 526 covers 20 Hz to 26.5 GHz. The N9020A was originally manufactured by Agilent Technologies and later supported by Keysight Technologies.[2][1]
| Designation | Generation | Vintage | Changes | Source |
|---|---|---|---|---|
| N9020A Option 503 | — | — | Frequency range 20 Hz to 3.6 GHz | keysight.com[2] |
| N9020A Option 508 | — | — | Frequency range 20 Hz to 8.4 GHz | keysight.com[2] |
| N9020A Option 513 | — | — | Frequency range 20 Hz to 13.6 GHz | keysight.com[2] |
| N9020A Option 526 | — | — | Frequency range 20 Hz to 26.5 GHz | keysight.com[2] |
| N9020A Option B85 | — | — | 85 MHz analysis bandwidth | keysight.com[1] |
| N9020A Option B1A | — | — | 125 MHz analysis bandwidth | keysight.com[1] |
| N9020A Option B1X | — | — | 160 MHz analysis bandwidth | keysight.com[1] |
| N9020A Option P03 | — | — | Preamplifier, 100 kHz to 3.6 GHz | keysight.com[1] |
| N9020A Option P08 | — | — | Preamplifier, 100 kHz to 8.4 GHz | keysight.com[1] |
| N9020A Option P13 | — | — | Preamplifier, 100 kHz to 13.6 GHz | keysight.com[1] |
| N9020A Option P26 | — | — | Preamplifier, 100 kHz to 26.5 GHz | keysight.com[1] |
Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The N9020A is offered with four frequency range options: Option 503 covers 10 Hz to 3.6 GHz, Option 508 covers 10 Hz to 8.4 GHz, Option 513 covers 10 Hz to 13.6 GHz, and Option 526 covers 10 Hz to 26.5 GHz.[1]
The frequency reference accuracy depends on the installed option. For the standard reference, the aging rate is ±1 x 10⁻⁶ per year, temperature stability is ±2 x 10⁻⁶ over the full range, and achievable initial calibration accuracy is ±1.4 x 10⁻⁶. With Option PFR (precision frequency reference), the aging rate is ±1 x 10⁻⁷ per year, temperature stability is ±5 x 10⁻⁸ over the full range, and initial calibration accuracy is ±4 x 10⁻⁸.[1]
The standard resolution bandwidth range is 1 Hz to 3 MHz in 10% steps, plus additional bandwidths of 4 MHz, 5 MHz, 6 MHz, and 8 MHz.[1]
The standard analysis bandwidth is 10 MHz. With options, the analysis bandwidth can be increased: Option B25 provides 25 MHz, Option B40 provides 40 MHz, Option B85 provides 85 MHz, Option B1A provides 125 MHz, and Option B1X provides 160 MHz.[1]
The following facts about the N 9020 A Signal Analyzer are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the N 9020 A Signal Analyzer are on record.
Answerable by: OEM historical records or a trade-press announcement
The control-system platform and OS era of the N 9020 A Signal Analyzer are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the N 9020 A Signal Analyzer are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
The process node or technology generation of the N 9020 A Signal Analyzer is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No publicly documented compatible parts, consumables, or accessories for the N 9020 A Signal Analyzer are on record.
Answerable by: an OEM parts catalog or a service engineer
No research found yet — worked with this tool? Share what you know.
Last updated Oct 9, 2026.
The ABM-407B-2-S-CE-S293 is a robot.