The Femtochrome FR 103 autocorrelator is a series of non-linear crystal autocorrelators for measuring the temporal width of ultrashort optical pulses. The FR-103XL variant offers a pulsewidth resolution of less than 1 fs and a wavelength range of 410 nm to 10 µm. The FR-103MN is a compact version with similar resolution and a wavelength range of 410 to 5000 nm.[1]

Femtochrome FR 103 Autocorrelator — Inventory photo
Fig. 01Femtochrome FR 103 AutocorrelatorInventory photo[2]

What it is

The Coherent Femtochrome FR 103 Autocorrelator is a laser pulse autocorrelator.[2][1]

Applications

The FR 103 is suited for low power lasers and for pulses from mode locked lasers over a broad wavelength range.[1]

What do the numbers mean?

Optics & imaging6

FR-103XL: Pulsewidth Resolution
<1 fs[1]
Accurate?
FR-103XL: Wavelength Range
410 nm - 10 µm[1]
Accurate?
FR-103MN: Wavelength Range
410 - 5000 nm[1]
Accurate?
FR-103WS: Pulsewidth Resolution
<2 fs[1]
Accurate?
FR-103MC: Wavelength Range
200 - 5000 nm[1]
Accurate?
FR-103TPM: Wavelength Range
700 - 2200 nm[1]
Accurate?

Configuration & options9

FR-103XL: Scan Range
~200 ps[1]
Accurate?
FR-103XL: Sensitivity
(PavPpk)min = 10⁻⁷ W² [w/PMT][1]
Accurate?
FR-103MN: Scan Range
>75 ps[1]
Accurate?
FR-103WS: Scan Range
>500 ps (1 ns option)[1]
Accurate?
FR-103HP: Pulsewidth Range
5 fs - 30 ps[1]
Accurate?
FR-103HP: Sensitivity
(PavPpk)min = 10⁻² W²[1]
Accurate?
FR-103MC: Pulsewidth Range
5 fs - 25 ps[1]
Accurate?
FR-103MC: Scan Range
>50 ps[1]
Accurate?
FR-103TPM: Pulsewidth Range
5 fs - 25 ps[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
FR-103XL——General purpose NL crystal (background-free) autocorrelator; pulsewidth resolution <1 fs; wavelength range 410 nm to 10 µm; scan range ~200 ps; sensitivity 10⁻⁷ W².dorgean.com[1]
FR-103MN——Compact version of FR-103XL; pulsewidth resolution <1 fs; wavelength range 410 to 5000 nm; scan range >75 ps; sensitivity 10⁻⁷ W².dorgean.com[1]
FR-103WS——Dispersion-free autocorrelator; pulsewidth resolution <2 fs; wavelength range 410 nm to 10 µm; scan range >500 ps (1 ns option); sensitivity 10⁻⁷ W².dorgean.com[1]
FR-103MC——Palm-size Two Photon Conductivity (TPC) interferometric autocorrelator; pulsewidths 5 fs to 25 ps; wavelength range 200 to 5000 nm; scan range >50 ps; any rep rate >100 Hz.dorgean.com[1]
FR-103TPM——High resolution interferometric TPC autocorrelator for multiphoton microscopy; wavelength range 700 to 2200 nm; pulsewidth range 5 fs to 25 ps.dorgean.com[1]
Interested in this tool?
Need help with this tool?Embed spec card

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Not publicly documented

The following facts about the Femtochrome FR 103 Autocorrelator are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Femtochrome FR 103 Autocorrelator are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the Femtochrome FR 103 Autocorrelator are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Femtochrome FR 103 Autocorrelator are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Femtochrome FR 103 Autocorrelator is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the Femtochrome FR 103 Autocorrelator are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]dorgean.com — dorgean.comdorgean.com
  2. [2]Inventory photo
Was this page accurate?

Last updated Sep 27, 2026.

Compare with similar tools

View all →