The Keysight N 9020 A is an MXA X-Series signal analyzer.[1][2]

How it works

The N 9020 A includes trigger modes for free run, line, video, external, RF burst, and periodic timer operation.[1][2]

Where it fits in the process flow

General reference — not yet source-verified

A signal analyzer belongs in test and characterization workflows rather than wafer fabrication steps.

Applications

The N 9020 A supports frequency-domain measurement of signals across radio-frequency and microwave ranges within its configured band limit.[1][2]

What do the numbers mean?

Power & electrical20

Frequency range (DC coupled, Option 503)
10 Hz to 3.6 GHz[1]
Accurate?
Frequency range (DC coupled, Option 508)
10 Hz to 8.4 GHz[1]
Accurate?
Frequency range (DC coupled, Option 513)
10 Hz to 13.6 GHz[1]
Accurate?
Frequency range (DC coupled, Option 526)
10 Hz to 26.5 GHz[1]
Accurate?
Frequency range (AC coupled, Option 503)
10 MHz to 3.6 GHz[2]
Accurate?
Frequency range (AC coupled, Option 508)
10 MHz to 8.4 GHz[2]
Accurate?
Frequency range (AC coupled, Option 513)
10 MHz to 13.6 GHz[2]
Accurate?
Frequency range (AC coupled, Option 526)
10 MHz to 26.5 GHz[2]
Accurate?
Maximum analysis bandwidth (standard)
10 MHz[1]
Accurate?
Maximum analysis bandwidth (Option B40)
40 MHz[1]
Accurate?
Maximum analysis bandwidth (Option B85)
85 MHz[1]
Accurate?
Maximum analysis bandwidth (Option B1A)
125 MHz[1]
Accurate?
Maximum analysis bandwidth (Option B1X)
160 MHz[1]
Accurate?
Resolution bandwidth range
1 Hz to 3 MHz (10% steps), 4, 5, 6, 8 MHz[1]
Accurate?
Phase noise at 10 kHz offset (CF=1 GHz, specification)
-135 dBc/Hz[1]
Accurate?
Displayed average noise level (DANL) at 10 MHz to 2.1 GHz (specification)
-144 dBm (1 Hz RBW, 0 dB atten, preamp off)[1]
Accurate?
Third-order intermodulation distortion (TOI) at 400 MHz to 1.7 GHz
+16 dBm typical[1]
Accurate?
Displayed average noise level (DANL) at 10 MHz to 2.1 GHz, typical
-153 dBm[1]
Accurate?
Phase noise at 10 kHz offset, CF=1 GHz, typical
-117 dBc/Hz[1]
Accurate?
Analysis bandwidth (maximum with Option B1X)
160 MHz[1]
Accurate?

Dimensions & facilities1

Net weight (without options)
18 kg (40 lbs)[1]
Accurate?

Configuration & options2

Operating temperature range
0 to 55 °C[1]
Accurate?
Maximum safe input level (average total power)
+30 dBm (1 W)[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
Option 503——Frequency range 10 Hz to 3.6 GHz (DC coupled) or 10 MHz to 3.6 GHz (AC coupled)keysight.com[1]
Option 508——Frequency range 10 Hz to 8.4 GHz (DC coupled) or 10 MHz to 8.4 GHz (AC coupled)keysight.com[1]
Option 513——Frequency range 10 Hz to 13.6 GHz (DC coupled) or 10 MHz to 13.6 GHz (AC coupled)keysight.com[1]
Option 526——Frequency range 10 Hz to 26.5 GHz (DC coupled) or 10 MHz to 26.5 GHz (AC coupled)keysight.com[1]
Option B25——Analysis bandwidth 25 MHzkeysight.com[1]
Option B40——Analysis bandwidth 40 MHzkeysight.com[1]
Option B85——Analysis bandwidth 85 MHzkeysight.com[1]
Option B1A——Analysis bandwidth 125 MHzkeysight.com[1]
Option B1X——Analysis bandwidth 160 MHzkeysight.com[1]
Option P03——Preamplifier, frequency range 100 kHz to 3.6 GHzkeysight.com[1]
Option P08——Preamplifier, frequency range 100 kHz to 8.4 GHzkeysight.com[1]
Option P13——Preamplifier, frequency range 100 kHz to 13.6 GHzkeysight.com[1]
Option P26——Preamplifier, frequency range 100 kHz to 26.5 GHzkeysight.com[1]
Option EA3——Electronic attenuator, frequency range 10 Hz to 3.6 GHz, attenuation range 0 to 24 dB in 1 dB stepskeysight.com[1]
Option NFE1 (NF2)——Noise Floor Extension, improves DANL by >9 dBkeysight.com[1]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Frequency range (DC coupled, Option 503)10 Hz to 3.6 GHz[1]
  • Frequency range (DC coupled, Option 508)10 Hz to 8.4 GHz[1]
  • Frequency range (DC coupled, Option 513)10 Hz to 13.6 GHz[1]
  • Frequency range (DC coupled, Option 526)10 Hz to 26.5 GHz[1]
  • Frequency range (AC coupled, Option 503)10 MHz to 3.6 GHz[2]
  • Frequency range (AC coupled, Option 508)10 MHz to 8.4 GHz[2]
  • Frequency range (AC coupled, Option 513)10 MHz to 13.6 GHz[2]
  • Frequency range (AC coupled, Option 526)10 MHz to 26.5 GHz[2]
  • Maximum analysis bandwidth (standard)10 MHz[1]
  • Maximum analysis bandwidth (Option B40)40 MHz[1]
  • Maximum analysis bandwidth (Option B85)85 MHz[1]
  • Maximum analysis bandwidth (Option B1A)125 MHz[1]
  • Maximum analysis bandwidth (Option B1X)160 MHz[1]
  • Resolution bandwidth range1 Hz to 3 MHz (10% steps), 4, 5, 6, 8 MHz[1]
  • Phase noise at 10 kHz offset (CF=1 GHz, specification)-135 dBc/Hz[1]
  • Displayed average noise level (DANL) at 10 MHz to 2.1 GHz (specification)-144 dBm (1 Hz RBW, 0 dB atten, preamp off)[1]
  • Third-order intermodulation distortion (TOI) at 400 MHz to 1.7 GHz+16 dBm typical[1]
  • Displayed average noise level (DANL) at 10 MHz to 2.1 GHz, typical-153 dBm[1]
  • Phase noise at 10 kHz offset, CF=1 GHz, typical-117 dBc/Hz[1]
  • Analysis bandwidth (maximum with Option B1X)160 MHz[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What are the analysis bandwidth options for the N9020A?

The N9020A offers analysis bandwidths of 25 MHz (standard), 40 MHz, 85 MHz, 125 MHz, and 160 MHz depending on the option installed.[1][2]

What is the standard local measurement update rate of the N9020A?

The N9020A has a standard local measurement and display update rate of 4 ms, corresponding to 250 updates per second.[1][2]

What resolution bandwidth (RBW) ranges are available on the N9020A?

The N9020A covers standard RBW from 1 Hz to 3 MHz in 10% steps, plus 4, 5, 6, and 8 MHz. With options, wider RBWs up to 70 MHz and 133 MHz are available.[1][2]

What trigger types are supported on the N9020A?

The N9020A supports free run, line, video, external 1, external 2, RF burst, and periodic timer triggers.[1]

Not publicly documented

The following facts about the N 9020 A are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the N 9020 A are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the N 9020 A are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the N 9020 A are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the N 9020 A is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the N 9020 A are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]keysight.com — keysight.comkeysight.com
  2. [2]testequipmenthq.com — testequipmenthq.comtestequipmenthq.com
  3. [3]Equipment inventory listing
Was this page accurate?

Last updated Oct 6, 2026.

Compare with similar tools

View all →