Waferpedia

Neslab

CFT 75 Chiller

Neslab CFT 75 Chiller family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Neslab CFT 75 Chiller is a single-phase air-cooled chiller. The Neslab CFT 75 Chiller has a temperature range of 5C to 35C. The Neslab CFT 75 Chiller has a cooling capacity of 2100 Watts at 20C.[1][2]

NeslabCFT 75 Chiller
No photo available yet

Power

Single phase[1]

Vacuum

3.8 GPM[1]

What it is

The CFT 75 is a recirculating chiller manufactured by Neslab. The CFT 75 is a single-phase air-cooled chiller. The CFT 75 refrigeration system uses R134a refrigerant. The CFT 75 is a CFC-free chiller.[3][2][1]

The CFT 75 succeeded the HX series of Neslab chillers. The CFT 75 is not available in a water-cooled configuration and supports a limited set of options.[1]

How it works

The CFT 75 uses an air-cooled refrigeration system. Air is drawn in the front of the unit and discharged through the rear and sides. The CFT 75 must be positioned so the intake and discharge airflow is not impeded. Inadequate ventilation reduces cooling capacity and can lead to compressor failure in extreme cases. The CFT 75 retains its full rated capacity in ambient temperatures up to approximately +38 °C.[2]

The plumbing connections are located on the rear of the unit and are labelled SUPPLY and RETURN or OUTLET and INLET. The supply and return connections are ½ inch NPT fittings. The SUPPLY fitting connects to the inlet of the instrument being cooled. The RETURN fitting connects to the outlet of the instrument being cooled. Tap water is the recommended cooling fluid for operation. The reservoir is filled through a square-nut plug located under a thumbscrewed access panel.[2]

A Main Power Switch starts and stops the unit. A Power Switch LED illuminates to indicate that the system is operating. A Cool LED indicates the status of the refrigeration system. The Cool LED illuminates while the refrigeration system removes heat from the cooling fluid. The Cool LED extinguishes as the operating temperature approaches the setpoint. After the unit is shut off, approximately five minutes should pass before restarting to allow the refrigeration pressures to equalize.[2]

Applications

The CFT 75 is a single-phase air-cooled chiller used across many industries.[1]

Why won't it start?

Documented failure modes, common issues, and field considerations.

  • Inadequate ventilation reduces cooling capacity.
  • Dust or debris on condenser fins can cause loss of cooling capacity.
  • If refrigeration pressures are not allowed to equalize after shutdown, the compressor can short-cycle and no cooling will occur.

What do the numbers mean?

Power & electrical12

Phase
Single phase[1]
Accurate?
Cooling capacity at 20C
2100 Watts[1]
Accurate?
Available voltage
200-230V 1 Ph[1]
Accurate?
Available voltage
115V 1 Ph[1]
Accurate?
Cooling capacity
2100 watts at 20°C[1]
Accurate?
Power requirements
208/230V, 60Hz[2]
Accurate?
Power requirements
220/240V, 50Hz[2]
Accurate?
Cooling capacity
2500 Watts (2100 Watts at 50Hz)[2]
Accurate?
Power requirements
208/230V, 60Hz; 220/240V, 50Hz[2]
Accurate?
Cooling capacity
2100 watts[1]
Accurate?
Power requirements
208/230V, 60Hz or 220/240V, 50Hz[2]
Accurate?
Pump capacity
4.0 LPM at 50 Hz; 10 LPM at 60 Hz[2]
Accurate?

Vacuum & pumping4

Flow rate at 20ºC / 30 PSI (PD2 Pump)
3.8 GPM[1]
Accurate?
Flow rate at 20°C / 30 PSI (PD1 Pump)
0.9 GPM[1]
Accurate?
Pump capacity
60 PSI / 30 Bar; flow 2.0 LPM (5 PSI) to 20 LPM (15-20 PSI) approx.[2]
Accurate?
Flow Rate at 20ºC / 30 PSI (PD1 Pump)
.9 GPM[1]
Accurate?

Dimensions & facilities2

Dimensions (H x W x D)
67.3 x 37.8 x 65.4 cm (26½ x 147/8 x 25¾ inches)[2]
Accurate?
Unit dimensions (H x W x D)
67.3 x 37.8 x 65.4 cm[2]
Accurate?

Configuration & options29

Make
Neslab[3]
Accurate?
Model
CFT 75[3]
Accurate?
Type
Recirculating chiller[2]
Accurate?
Refrigeration system
Air-cooled[2]
Accurate?
Temperature range
5C to 35C[1]
Accurate?
Plumbing connections
1/2 inch NPT[2]
Accurate?
Cooling fluid
Tap water is the recommended fluid for operation.[2]
Accurate?
Cooling system
Air-cooled refrigeration system[2]
Accurate?
Temperature range
+5°C to +30°C[2]
Accurate?
Reservoir volume
6.8 liters (1.8 gallons)[2]
Accurate?
Refrigerant
R134a[2]
Accurate?
Air intake required
800 cubic feet per minute[2]
Accurate?
Model
CFT 75 / CFT-75[3]
Accurate?
Refrigerant
R134a, CFC-free[2]
Accurate?
Temperature range
+5°C to +30°C (Trillium lists CFT75 range as 5C to 35C)[2]
Accurate?
Temperature stability
±0.5°[2]
Accurate?
Cooling options
Air only[1]
Accurate?
Plumbing connections
½ inch NPT, labelled SUPPLY and RETURN[2]
Accurate?
Condenser
Air-cooled; air drawn in the front and discharged through rear and side[2]
Accurate?
Compliance
CE label; LVD 73/23/EEC; UL 3101-1:93; EMC 89/336/EEC EN 55011 Class A[2]
Accurate?
Fluid viscosity requirement
50 centistokes or less at lowest operating temperature[2]
Accurate?
Full rated capacity ambient temperature
Up to approximately +38°C[2]
Accurate?
Air intake requirement
Approximately 800 cubic feet per minute for full rated capacity[2]
Accurate?
OEM
Neslab[3]
Accurate?
Cooling configuration
Air only[1]
Accurate?
Cooling fluid recommendation
Tap water[2]
Accurate?
Cooling type
Air cooled[2]
Accurate?
Cooling capacity at 20°C
2100 W[1]
Accurate?
Plumbing connections
SUPPLY and RETURN, 1/2 inch NPT[2]
Accurate?

Vintage & configurations

  1. 2009service-business acquisition[1]

    Trillium acquired the chiller and heat exchanger service business from Air Products in 2009.

Documented models & variants

DesignationGenerationVintageChangesSource
CFT75 (R134a)——Identified in the manual title as a CFC-Free CFT-75 Recirculating Chiller.chillercity.com[2]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • PhaseSingle phase[1]
  • Flow rate at 20ºC / 30 PSI (PD2 Pump)3.8 GPM[1]
  • Cooling capacity at 20C2100 Watts[1]
  • Available voltage200-230V 1 Ph[1]
  • Available voltage115V 1 Ph[1]
  • Cooling capacity2100 watts at 20°C[1]
  • Power requirements208/230V, 60Hz[2]
  • Power requirements220/240V, 50Hz[2]
  • Flow rate at 20°C / 30 PSI (PD1 Pump)0.9 GPM[1]
  • Cooling capacity2500 Watts (2100 Watts at 50Hz)[2]
  • Power requirements208/230V, 60Hz; 220/240V, 50Hz[2]
  • Pump capacity60 PSI / 30 Bar; flow 2.0 LPM (5 PSI) to 20 LPM (15-20 PSI) approx.[2]
  • Flow Rate at 20ºC / 30 PSI (PD1 Pump).9 GPM[1]
  • Cooling capacity2100 watts[1]
  • Power requirements208/230V, 60Hz or 220/240V, 50Hz[2]
  • Pump capacity4.0 LPM at 50 Hz; 10 LPM at 60 Hz[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of cooling system is the Neslab CFT 75 Chiller?

The Neslab CFT 75 Chiller is a recirculating chiller with an air-cooled refrigeration system.[2]

How are the fluid connections arranged on the Neslab CFT 75 Chiller?

The Neslab CFT 75 Chiller has rear plumbing connections labeled SUPPLY and RETURN or OUTLET and INLET, and the fittings are 1/2 inch NPT.[2]

How should airflow be handled around the unit?

The unit should be positioned so that intake and discharge airflow are not impeded.[2]

Not publicly documented

The following facts about the CFT 75 Chiller are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • The control-system platform and OS era of the CFT 75 Chiller are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • The process node or technology generation of the CFT 75 Chiller is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the CFT 75 Chiller are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the CFT 75 Chiller are on record.

    Answerable by: university cleanroom staff or an OEM application specialist

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]trilliumus.com — trilliumus.comtrilliumus.com
  2. [2]chillercity.com — chillercity.comchillercity.com
  3. [3]Equipment inventory listing
Was this page accurate?

Last updated Oct 8, 2026.