Thermo Fisher
Provisional entry — research in progress
This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.
The Thermo Fisher Orbitrap Velos Pro is a hybrid mass spectrometer. The Thermo Fisher Orbitrap Velos Pro combines a Velos Pro dual-cell linear trap with an Orbitrap analyzer. The Thermo Fisher Orbitrap Velos Pro ETD mass spectrometer adds a reagent ion source for Electron Transfer Dissociation analyses.[1]

The Thermo Fisher Orbitrap Velos Pro is a hybrid mass spectrometer that combines a linear ion trap with an Orbitrap mass analyzer. The instrument belongs to the LTQ family of hybrid mass spectrometers.[1]
The Orbitrap Velos Pro sits in an analytical measurement workflow after sample preparation and ionization. The instrument receives ions from an external source and performs mass analysis on the resulting ion population.
| Designation | Generation | Vintage | Changes | Source |
|---|---|---|---|---|
| Orbitrap Velos Pro ETD | — | 2011 | ETD Module is physically coupled to the back of the Orbitrap Velos Pro mass spectrometer. | documents.thermofisher.com[1] |
Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The mass range is m/z 50–2,000 and m/z 200–4,000.[5]
The resolution is 60,000 at m/z 400 at a scan rate of 1 Hz, with a minimum resolution of 7,500 and a maximum resolution greater than 100,000 at m/z 400.[5]
Mass accuracy is less than 3 ppm RMS with external calibration and less than 1 ppm RMS using internal calibration.[5]
Using electrospray ionization, injection of 2 μL of a 50 fg/μL solution of reserpine (100 femtograms total) at 500 μL/min produces a minimum signal-to-noise ratio of 100:1 for the transition of m/z 609 to m/z 397 and m/z 448 when operating at unit resolution in full-scan MS/MS mode.[5]
The dynamic range is greater than 5,000 within a single scan, guaranteeing specified mass accuracy.[5]
The instrument supports CID, HCD, and optionally ETD. The HCD collision cell includes an axial field gradient for improved efficiency.[5]
The following facts about the Orbitrap Velos Pro are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
The control-system platform and OS era of the Orbitrap Velos Pro are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the Orbitrap Velos Pro are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
The process node or technology generation of the Orbitrap Velos Pro is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No publicly documented compatible parts, consumables, or accessories for the Orbitrap Velos Pro are on record.
Answerable by: an OEM parts catalog or a service engineer
No publicly hosted manuals, SOPs, or datasheets for the Orbitrap Velos Pro are on record.
Answerable by: university cleanroom staff or an OEM application specialist
No research found yet — worked with this tool? Share what you know.
Last updated Oct 4, 2026.
The Perkin Elmer 1050 UV-VIS Spectrometer is an instrument used for analyzing ultraviolet and visible light absorption spectra.
The Agilent 11980 A is a fiber optic interferometer for precision optical measurements.