Power

1000Vmax current:10A[1]

Performance

±(0.2% + 10 counts)[2]

What is it?

The Advantest TR6846 is a 4.5-digit desktop digital multimeter designed for precise measurement of voltage, current, resistance, capacitance, frequency, and temperature.

What do the numbers mean?

Power & electrical9

max voltage
1000Vmax current:10A[1]
Accurate?
DC Voltage range
0.01mV to 1000V[2]
Accurate?
AC Voltage range
0.01mV to 1000V[2]
Accurate?
DC Voltage range (alternate)
1µV to 1kV[1]
Accurate?
AC Voltage range (alternate)
10µV to 750V[1]
Accurate?
Frequency range
0.01Hz to 1MHz[2]
Accurate?
Basic accuracy (DC Voltage)
±(0.02% + 2 counts)[2]
Accurate?
Basic accuracy (AC Voltage)
±(0.2% + 10 counts)[2]
Accurate?
Power Source
AC 100V to 240V, 50/60Hz[2]
Accurate?

Performance6

Basic accuracy (DC Current)
±(0.2% + 10 counts)[2]
Accurate?
Basic accuracy (AC Current)
±(0.5% + 20 counts)[2]
Accurate?
Basic accuracy (Resistance)
±(0.2% + 5 counts)[2]
Accurate?
Basic accuracy (Capacitance)
±(0.5% + 20 counts)[2]
Accurate?
Basic accuracy (Frequency)
±(0.1% + 5 counts)[2]
Accurate?
Basic accuracy (Temperature)
±(0.3% + 2°C)[2]
Accurate?

Control & software1

Features
Auto-ranging and manual-ranging modes, True RMS AC measurements, Data hold, Relative mode, Diode and continuity tests, Auto power-off, RS-232 interface, Built-in math functions (dB, dBm), Overload protection[2]
Accurate?

Dimensions & facilities5

Dimensions (W x H x D)
216mm x 88mm x 290mm[2]
Accurate?
Dimensions (alternate)
190mm x 76mm x 260mm[1]
Accurate?
Dimensions (alternate 2)
190mm x 70mm x 260mm[3]
Accurate?
Weight
2.5kg[2]
Accurate?
Weight (alternate)
about 2.1kg[1]
Accurate?

Configuration & options8

Resistance
1mO ~ 300MO,[1]
Accurate?
Attachments
3 Files[1]
Accurate?
Display
4.5 digit LED[2]
Accurate?
DC Current range
0.1μA to 10A[2]
Accurate?
AC Current range
0.1μA to 10A[2]
Accurate?
Resistance range
0.01Ω to 100MΩ[2]
Accurate?
Capacitance range
0.01pF to 100μF[2]
Accurate?
Temperature range
-50°C to 1000°C[2]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • max voltage1000Vmax current:10A[1]
  • DC Voltage range0.01mV to 1000V[2]
  • AC Voltage range0.01mV to 1000V[2]
  • DC Voltage range (alternate)1µV to 1kV[1]
  • AC Voltage range (alternate)10µV to 750V[1]
  • Frequency range0.01Hz to 1MHz[2]
  • Basic accuracy (DC Voltage)±(0.02% + 2 counts)[2]
  • Basic accuracy (AC Voltage)±(0.2% + 10 counts)[2]
  • Power SourceAC 100V to 240V, 50/60Hz[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of display does the TR6846 have?

The TR6846 has a 4.5 digit LED display.[2]

What is the DC voltage measurement range?

The DC voltage range is 0.01 mV to 1000 V.[2]

What communication interface does the TR6846 offer?

The TR6846 includes an RS-232 interface for PC connectivity.[2]

What is the basic DC voltage accuracy?

Basic DC voltage accuracy is ±(0.02% + 2 counts).[2]

Does the TR6846 support true RMS AC measurements?

Yes, the TR6846 provides true RMS AC measurements.[2]

Not publicly documented

The following facts about the TR6846 Digital Multimeter are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the TR6846 Digital Multimeter are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the TR6846 Digital Multimeter are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the TR6846 Digital Multimeter are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the TR6846 Digital Multimeter are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the TR6846 Digital Multimeter is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]dealer listingfabsurplus.com
  2. [2]microprecision.com — microprecision.commicroprecision.com
  3. [3]y-d.co.jpy-d.co.jp
Was this page accurate?

Last updated Sep 24, 2026.

Compare with similar tools

View all →