What it is

The Hitachi U 3900 is a UV-visible spectrophotometer. The U-3900 is a double-beam, single-monochromator system in the U-3900/3900H research-grade family.[2]

How it works

The U-3900 uses a single photomultiplier detector and supports variable band pass settings and multiple scan speeds. The U-3900 family also includes a standard sample compartment for accessories, automatic calibration, and self-diagnosis functions.[2]

Where it fits in the process flow

The U-3900 family supports measurements on solutions, thin films, turbid samples, reflectance samples, and flow-through setups through compatible accessories. The instrument also supports micro-quantity measurement through micro-focusing optics and automatic cell-length conversion.[2]

Applications

The U-3900 family serves basic research, biotechnology, and new materials work. The instrument is also used for quantitative analysis and data reporting in laboratory environments.[2]

The U-3900 supports measurements of soft, hard, and intraocular contact lenses with the integrating sphere method. The instrument also supports high-absorbance and low-transmittance measurements in the U-3900H configuration.[2]

What do the numbers mean?

Power & electrical1

Power requirements
100, 120, 220, 230 or 240 V AC, 50/60 Hz, 300 VA[2]
Accurate?

Optics & imaging4

Wavelength range
190 to 900 nm[2]
Accurate?
Band pass
Variable 0.1, 0.5, 1, 2, 4, and 5 nm[2]
Accurate?
Scan speed
1.5, 3, 15, 30, 60, 120, 300, 600, 1200, 1800, 2400 nm/min[2]
Accurate?
Detector
Single photomultiplier[2]
Accurate?

Dimensions & facilities2

Dimensions
680 (W) x 692 (D) x 257 (H) mm; 27 in (W) x 27 in (D) x 10 in (H)[2]
Accurate?
Weight
Approx. 45 kg (100 lbs)[2]
Accurate?

Configuration & options3

P/N
2J2-0012[1]
Accurate?
Type
Double-beam, single-monochromator UV-visible spectrophotometer[2]
Accurate?
Vintage
2009[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
U-3900H——Double-beam, double-monochromator system; supports high absorbance measurements and low transmittance.web.archive.org[2]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Power requirements100, 120, 220, 230 or 240 V AC, 50/60 Hz, 300 VA[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of instrument is the Hitachi U 3900?

The Hitachi U 3900 is a UV-visible spectrophotometer.[2]

What is the optical architecture of the U-3900?

The U-3900 is a double-beam, single-monochromator system.[2]

What wavelength range does the U-3900 cover?

The U-3900 covers a wavelength range from 190 to 900 nm.[2]

What band pass settings are specified for the U-3900?

The U-3900 has variable band pass settings of 0.1, 0.5, 1, 2, 4, and 5 nm.[2]

What detector does the U-3900 use?

The U-3900 uses a single photomultiplier detector.[2]

Not publicly documented

The following facts about the U 3900 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the U 3900 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the U 3900 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the U 3900 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the U 3900 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the U 3900 are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]inventory listing
  2. [2]web.archive.org — hitachi-hightech.com (Jul 26, 2021)web.archive.org
Was this page accurate?

Last updated Oct 3, 2026.

Compare with similar tools

View all →