Waferpedia

Keysight

4339 B High Resistance Meter

Test & ProbeKeysight 43xx family
Research Quality: 50% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Keysight 4339 B High Resistance Meter is a precision bench-top instrument for accurate high resistance and low current tests. The Keysight 4339 B High Resistance Meter has one test channel. The Keysight 4339 B High Resistance Meter is specified with 0.6% basic accuracy.[1]

4339 B High Resistance Meter — Inventory photo
Fig. 014339 B High Resistance MeterInventory photo[2]

Performance

0.6%[1]

Optics

3 / 4 / 5 digits[1]

What it is

The Keysight 4339 B High Resistance Meter is a bench-top instrument for ultra-high-resistance and low-current measurement.[1]

The 4339 B is a single-channel meter with a built-in dc test voltage source and measurement functions for resistance, current, surface resistivity, and volume resistivity.[1]

How it works

The 4339 B provides dc test voltage from zero to one kilovolt in steps, supports open error correction to reduce fixture and cable parasitics, and includes contact check, comparator, save and recall, and test-sequence functions.[1]

The 4339 B supports automated control through GPIB and can use trigger and handler interface signals for external integration.[1]

Where it fits in the process flow

General reference — not yet source-verified

A high resistance meter belongs in electrical characterization and quality verification rather than in wafer fabrication steps that change the material.

Applications

The 4339 B is used for precision high resistance and low current tests in manufacturing environments and for bench-top characterization of samples and devices.[1]

The 4339 B supports resistivity measurements for solid samples and high-voltage testing of discrete components when used with appropriate fixtures and leads.[1]

What do the numbers mean?

Power & electrical2

DC test voltage
0 V to 1000 V, 0.1 V steps up to 200 V and 1.0 V steps above 200 V[1]
Accurate?
Max current
10 mA at ≤ 100 V, 5 mA at ≤ 250 V, 2 mA at ≤ 500 V, 1 mA at ≤ 1 kV[1]
Accurate?

Optics & imaging1

Display resolution
3 / 4 / 5 digits[1]
Accurate?

Performance1

Basic accuracy
0.6%[1]
Accurate?

Dimensions & facilities2

Physical dimensions
320(W) x 100(H) x 450(D) mm[1]
Accurate?
Weight
6.5 kg (typical)[1]
Accurate?

Configuration & options10

REV
01.05[2]
Accurate?
Unit powers on and passes self-test sequence[2]
Accurate?
Agilent ground to guard short / jumper included with unit[2]
Accurate?
OEM
Keysight / Agilent[2]
Accurate?
Model
4339 B[2]
Accurate?
Instrument type
High Resistance Meter[2]
Accurate?
Test channels
1[1]
Accurate?
Measurement parameters
R, I, pv, ps[1]
Accurate?
Measurement range (resistance)
10^3 to 1.6 x 10^16 Ω[1]
Accurate?
Measurement range (current)
60 fA to 100 μA[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • DC test voltage0 V to 1000 V, 0.1 V steps up to 200 V and 1.0 V steps above 200 V[1]
  • Max current10 mA at ≤ 100 V, 5 mA at ≤ 250 V, 2 mA at ≤ 500 V, 1 mA at ≤ 1 kV[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

How many test channels does the 4339 B have?

The 4339 B has one test channel.[1]

What measurement types does the 4339 B support?

The 4339 B supports resistance, current, surface resistivity, and volume resistivity measurements.[1]

What is the dc test voltage range of the 4339 B?

The 4339 B provides dc test voltage from zero to one kilovolt.[1]

Does the 4339 B include open error correction?

The 4339 B includes open error correction to compensate for leakage current and capacitance in test fixtures and cables.[1]

What interfaces are available for external control?

The 4339 B supports GPIB control and a handler interface.[1]

Not publicly documented

The following facts about the 4339 B High Resistance Meter are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 4339 B High Resistance Meter are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the 4339 B High Resistance Meter are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 4339 B High Resistance Meter are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 4339 B High Resistance Meter are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 4339 B High Resistance Meter is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]testequipmenthq.com — testequipmenthq.comtestequipmenthq.com
  2. [2]Inventory photo
Was this page accurate?

Last updated Oct 8, 2026.

Compare with similar tools

View all →