The Varian 2100CD offers photon energy configurations of 6 MV and up to 10, 15, 18, or 25 MV depending on the variant. For photon mode, the maximum dose rate is 600 monitor units per minute. Electron beam energies are also available with a maximum dose rate of 1000 monitor units per minute.[1]
The Varian 2100CD can be equipped with either an 80-leaf multi-leaf collimator (MLC) covering a maximum field size of 40 by 40 centimeters, or a 120-leaf MLC of the same field size. The 120-leaf version uses 5-millimeter leaf width in the central 20 centimeters and 10-millimeter width in the outer 20 centimeters. An optional on-board imager (OBI) enables kV imaging and cone-beam CT for image-guided radiation therapy.[1]
The Varian 2100CD supports 3D conformal radiation therapy and intensity-modulated radiation therapy (IMRT). Optional capabilities include stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) when fitted with cones or a micro-MLC. Volumetric modulated arc therapy (VMAT) is available only if the optional OBI system is installed.[1]
With its optional stereotactic radiosurgery capability, the Varian 2100CD can deliver highly focused radiation to small intracranial lesions using cones or a micro-MLC. The optional OBI system enables image-guided radiation therapy (IGRT) by acquiring kV X-ray images or cone-beam CT scans immediately before or during treatment.[1]
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The following facts about the 2100CD are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
No publicly documented variants, configuration options, or revision breakpoints of the 2100CD are on record.
Answerable by: an OEM product catalog or an engineer who ordered or specified the tool
The control-system platform and OS era of the 2100CD are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the 2100CD are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
The process node or technology generation of the 2100CD is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No publicly documented compatible parts, consumables, or accessories for the 2100CD are on record.
Answerable by: an OEM parts catalog or a service engineer
No research found yet — worked with this tool? Share what you know.
Last updated Sep 22, 2026.